- Product deformation, dimensional change
- Electronic components characteristics changes
- Life time reduction
- High pressure in tight area
- Lubricant property change
- Devolatilisation material
- Hardening material
- Cracks apparition
- Mechanical bending
Climatic tests consist in reproducing terrestrial climatic conditions or increasing them.
These tests may be functional tests (in this case we verify equipments operating faculties at extreme conditions) or accelerated ageing tests (climatic conditions increase without reaching destruction threshold.)
Temperature range: from -75°C to +300°C
Rate of change : from 3°C/min to 15°C/min
Temperature range: from -75°C to +180°C
Time transfer: <10s
Mobil part looseness
Component break or deformation
Cracks apparition
Insulation trouble apparition
Electronic components characteristics changes
Efficiency reducing of protective chemical agents
Electrical and mechanical trouble due to quick water or ice generation
Excessive static electricity
Temperature range: from -75°C to+180°C
Humidity range: from 10% to 99%
Oxidation or corrosion
Cracks apparition
Swelling material because of pumping phenomenon
Mechanical resistance looseness
Electronic components characteristics changes
Composite material delamination
Short circuit apparition
Plasticity or elasticity characteristic change