Testing services > Climatic testing
Climatic testing
Low and high temperature testing, Rapid variation temperature testing
- Controlled environment chamber
- Temperature range: -75 to +300°C
- Net capacity: until 28m³
- Rate of temperature change: until 15°C/min
Main failure modes provided by high and low temperature testing
- Product deformation, dimensional change
- Electronic components characteristics changes
- Life time reduction
- High pressure in tight area
- Lubricant property change
- Devolatilisation material
- Hardening material
- Cracks apparition
Damp heat testing
- Damp heat testing chamber
- Temperature range: -75 to +180°C
- Humidity range: 10 to 99 %
- Net capacity: until 28m³
- Rate of temperature change: until 15°C/min
Main failure modes provided by damp heat testing
- Oxidation or corrosion
- Cracks apparition
- Swelling material because of pumping phenomenon
- Mechanical resistance looseness
- Electronic components characteristics changes
- Composite material delamination
- Short circuit apparition
- Plasticity or elasticity characteristic change
Thermal shocks testing
- Thermal shocks chamber
- Temperature range: -75 to +180°C
- Net capacity: until 280dm³
- Time transfer: < 10 seconds
Main failure modes provided by thermal shock testing
- Mobil part looseness
- Component break or deformation
- Cracks apparition
- Insulation trouble apparition
- Electronic components characteristics changes
- Protection chemical agent efficiency diminution
- Electrical and mechanical trouble because of quick water of ice generation
- Excessive static electricity